Solid-state Timer H3BA-N Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 20), and Safety Precautions (page 16). Solid-state Timer with Valuable Multiple-time Ranges and Multiple-operating Modes * Handles a wide range of applications through six operating modes. * With H3BA-N8H models, the output type can be switched between time-limit DPDT and time-limit SPDT + instantaneous SPDT using a selector. * Setting rings (order separately) to enable consistent settings and to limit the setting range. * Panel Covers (order separately) to enable various panel designs. * Conforms to LR and approved by UL and CSA. RC Broad Line-up of H3B@-N Series H3B@-N H3BA-N Multi-functional Timer 11-pin model H3BA-N 8-pin with H3BA-N8H H3BF-N Twin Timer H3BF-N8 8-pin model H3BG-N H3BH-N Star-delta Timer 8-pin model H3BG-N8 8-pin with H3BG-N8H instantaneous contact output and time-limit output Note: Refer to the H3BF-N/BG-N/BH-N Datasheet (Cat. No. L094-E1-1) for details. Power OFF-delay Timer 8-pin model H3BH-N8 instantaneous contact output Solid-state Timer H3BA-N 1 Model Number Structure Model Number Legend H3BA-N@ 1 1. Number of Pins/Output None: 11-pin models/Time-limit DPDT 8H: 8-pin models/Time-limit SPDT and switchable SPDT (time-limit instantaneous) Ordering Information List of Models Control output Supply voltage Contact output: DPDT (time-limit output) Contact output: Time-limit SPDT and switchable SPDT (time-limit instantaneous) 11-pin models 110 VAC (50/60 Hz) H3BA-N 110 VAC 220 VAC (50/60 Hz) H3BA-N 220 VAC 24 VDC H3BA-N 24 VDC 110 VAC (50/60 Hz) --- 8-pin models --- H3BA-N8H 110 VAC 220 VAC (50/60 Hz) H3BA-N8H 220 VAC 24 VDC H3BA-N8H 24 VDC Accessories (Order Separately) Name/specifications Flush Mounting Adapters Models Y92F-30 Y92F-70 Y92F-71 Mounting Tracks 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Protective Cover Y92A-48B Track Mounting/ Front Connecting Sockets 8-pin P2CF-08 11-pin P2CF-11 Back Connecting Sockets 8-pin P3G-08 11-pin P3GA-11 Setting a specific time Y92S-27 Limiting the setting range Y92S-28 Light gray (5Y7/1) Y92P-48GL Black (N1.5) Y92P-48GB Medium gray (5Y5/1) Y92P-48GM For PL08 Socket Y92H-1 For PF085A Socket Y92H-2 Time Setting Ranges Panel Covers (See note 1.) Hold-down Clips (See note 2.) Note: 1. The Time Setting Ring and Panel Cover are sold together. 2. Hold-down Clips are sold in sets of two. 2 Solid-state Timer H3BA-N Specifications General Item H3BA-N H3BA-N8H A: ON-delay H: ON-delay with instantaneous output contact Operating mode A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval Pin type 11-pin 8-pin Input type No-voltage input --- Output type DPDT (time-limit) SPDT (time-limit) and switchable SPDT (time-limit <---> instantaneous) Mounting method DIN track mounting, surface mounting, and flush mounting Approved standards UL508, CSA C22.2 No.14, Conforms to LR (currently under application and approval is expected by the end of Feb. 2006) Time Ranges Time unit Setting s (sec) min x 10 h (10 h) h (hrs) 1.2 0.05 to 1.2 0.12 to 1.2 1.2 to 12 3 0.3 to 3 3 to 30 12 1.2 to 12 12 to 120 30 3 to 30 30 to 300 Ratings Item H3BA-N Rated supply voltage (See notes 1 and 2) 110 VAC (50/60 Hz), 220 VAC (50/60 Hz), 24 VDC Operating voltage range (See note 3) 85% to 110% of rated supply voltage Power reset Minimum power-opening time: 0.1 s No-voltage input ON impedance: 1 k max. ON residual voltage: 1 V max. OFF impedance: 200 k min. Power consumption 110 VAC: Approx. 4.6 VA (1.5 W) 220 VAC: Approx. 7.9 VA (1.3 W) 24 VDC: Approx. 0.6 W Control outputs Contact: H3BA-N8H 110 VAC: Approx. 3.6 VA (1.6 W) 220 VAC: Approx. 5.4 VA (1.4 W) 24 VDC: Approx. 0.9 W 5 A at 250 VAC, resistance load (cos = 1) Note: 1. DC ripple rate: 20% max. 2. Models other than 24-VDC H3BA-N models cause an inrush current. Pay careful attention when attempting to turn on power to such models with non-contact output from a device such as a sensor. 3. 90% or higher if the Timer is used continuously at a high ambient temperature. Solid-state Timer H3BA-N 3 Characteristics Item H3BA-N H3BA-N8H Accuracy of operating time 0.3% FS max. ( 0.3%10 ms in a range of 1.2 s) Setting error 5% FS 0.05 s max. Reset time Min. power-opening time: 0.1 s max. Min. pulse-input time: 50 ms Influence of voltage 0.5% FS max. ( 0.5%10 ms in a range of 1.2 s) Influence of temperature 2% FS max. (2%10 ms in a range of 1.2 s) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit 1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other (750 VAC for H3BA-N8H) Impulse withstand voltage 1 kV (between power terminals) 2 kV (between current-carrying terminal and exposed non-current-carrying metal parts, 1.5 kV for 24-VDC models) Noise immunity AC models: 1.5 kV (between power terminals), and 600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) DC models: 480 V (between power terminals), and 600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Static immunity Malfunction: 4 kV Destruction: 8 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions Shock resistance Destruction: 1,000 m/s2 (approx. 100G) each in three directions Malfunction: 100 m/s2 (approx. 10G) each in three directions Ambient temperature Operating: -10C to 55C (with no icing) Storage: -25C to 65C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20 million operations min. (under no load Mechanical: 10 million operations min. (under no at 1,800 operations/h) load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, Electrical: 100,000 operations min. (5 A at 250 resistive load at 1,800 operations/h) VAC, resistive load at 360 operations/h) Case color Light gray (Munsell 5Y7/1) Enclosure ratings IEC: IP40 (panel surface) Weight Approx. 95 g Note: For setting the time-limit of the Timer to a cycle of less than 3 seconds or applying the forced reset, use the H3BA-N in mode D (signal OFFdelay). Nomenclature H3BA-N H3BA-N8H Power Indicator (Green): Lit when Timer operates. PW Output Indicator (Orange): Lit when Timer outputs. Power Indicator (Green): Lit when Timer operates. PW MODE A Operating Mode Selector: Select a mode from A, B, B2, C, D, and E UP 1.5 2 1 2.5 0.5 Time Range Selector: Select one from 1.2, 3, 12, and 30. Operating Mode Display Window Scale Range Display Windows 3 0 Output Indicator (Orange): Lit when Timer outputs. Time Range Selector: Select one from 1.2, 3, 12, and 30. MODE A UP 1.5 4 2 1 2.5 0.5 Output Type Selector: Select a type from A and H A: Time-limit DPDT (default setting) H: Time-limit SPDT and instantaneous SPDT Scale Range Display Windows 3 0 sec sec H3BA H3BA Time setting knob (set time) Output Type Display Window Time Unit Selector Select a unit from sec, min, hrs, and 10h. Solid-state Timer H3BA-N Time setting knob (set time) Time Unit Selector Select a unit from sec, min, hrs, and 10 h. Operation Block Diagrams H3BA-N AC (DC) input Power supply circuit Oscillation circuit Reset input, start input, and gate input Time range/ unit selectors Operating mode selector Counting circuit Output circuit Indicator circuit Input circuit Power-ON Output-ON indicator indicator H3BA-N8H AC (DC) input Power supply circuit Oscillation circuit Time range/ unit selectors Output type selector Counting circuit Output circuit Indicator circuit Power-ON Output-ON indicator indicator Instantaneous output circuit I/O Functions Inputs Outputs Start Starts time-measurement. Reset Interrupts time-measurement and resets time-measurement value. No time-measurement is made and control output is OFF while the reset input is ON. Gate Prohibits time-measurement. Control output Outputs are turned ON according to designated output mode when preset value is reached. Solid-state Timer H3BA-N 5 Basic Setting Using the Setting Ring Setting of Selector Setting a Specific Time The selectors can be turned clockwise and counterclockwise to select the desired time unit, time range, output type (only for H3BAN8H) or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position at which it is secured. Do not set it midway between two securing positions or a malfunction could result from improper setting. Mount the Panel Cover on the Timer, set the desired time with the time setting knob, and place Time Setting Ring A onto the time setting knob so that the time setting notch of Time Setting Ring A is in the center of the reset lock position of the Panel Cover. Time setting Reset lock position notch Operating mode selector/ Output type selector Operating mode/ Output type display window Time setting ring A Panel cover Time setting notch Setting position Groove for screwdriver Selection of Operating Mode with H3BA-N Turn the operating mode selector with a screwdriver until the desired operating mode (A, B, B2, C, D, or E) appears in the display window located above the selector. Selection of Output Type with H3BA-N8H Turn the output type selector with a screwdriver until the desired output type (A or H) appears in the display window located above the selector. Selection of Time Unit and Time Range The desired time unit (sec, min, hrs, or 10h) is displayed in the window below the time setting knob by turning the time unit selector located at the lower right corner of the front panel. A time range (1.2, 3, 12, or 30) is selected with the time range selector at the lower left corner of the front panel, and the selected time range appears (in the window at the lower right part) within the plastic frame of the time setting knob. Example: To set the time to 10 s. Limiting the Setting Range Example: To set a range of 10 and 20 s. Mount the Panel Cover on the Timer, set the time setting knob to 10 s (the lower limit of the setting range), and place Time Setting Ring C onto the time setting knob so that the stopper of Time Setting Ring C is on the right edge of the reset lock position of the Panel cover. Next, set the time setting knob to 20 s (the upper limit of the setting range), place Time Setting Ring B onto the time setting knob so that the stopper of Time Setting Ring B is on the left edge of the reset lock position of the Panel Cover. Stopper Time setting ring B Time range selector Operating mode display window Time unit selector Time unit display window Setting of Time Use the time setting knob to set the desired time. 6 Solid-state Timer H3BA-N Reset lock position Time setting ring C Panel cover Range Timing Chart Note: 1. The minimum power-opening time ("Rt") is 0.1 s and the minimum pulse width is 0.05 s. 2. The letter "t" in the timing charts stands for the set time and "t-a" means that the period is less than the time set. H3BA-N Operating mode Timing chart A: ON-delay t t Power 2 and 10 Basic operation Start 2 and 6 Reset 2 and 7 Power Output relay (NC) 1 and 4 (11 and 8) Start Output relay (NO) 1 and 3 (11 and 9) and output indicator t Output Power indicator B: Flicker OFF start t-a t t t t t Power 2 and 10 Basic operation Start 2 and 6 Reset 2 and 7 Output relay (NC) 1 and 4 (11 and 8) Power Start Output relay (NO) 1 and 3 (11 and 9) and output indicator t t t t t t t Output Power indicator B2: Flicker ON start t-a t t t t t Power 2 and 10 Basic operation Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power Start t Output Power indicator C: Signal ON/OFF-delay t-a t Power 2 and 10 t t-a t t-a t Basic operation Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Power Start t t t t Output Solid-state Timer H3BA-N 7 Operating mode Timing chart D: Signal OFF-delay t-a t-a t t-a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Basic operation Power Start t Output E: Interval t t t-a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Basic operation Power Start t Output Gate Signal Input in Operating Mode A (ON-delay Operation) t1 t2 ON Power OFF ON Start OFF ON Gate OFF ON Reset OFF Output ON relay OFF Note: The set time is the sum of t1 and t2. 8 Solid-state Timer H3BA-N t-a t H3BA-N8H, Output Type: A Type Operating mode Timing chart A: ON-delay Rt t Rt t t-a Power 2 and 7 Output relay (NC) 8 and 5 (1 and 4) Output relay (NO) 8 and 6 (1 and 3) and output indicator Power indicator Basic operation Power t Output H3BA-N8H, Output Type: H Type Operating mode H: ON-delay with instantaneous output contact Timing chart Rt t t Rt t-a Power 2 and 7 Output relay 8 and 5 (NC) Output relay 8 and 6 (NO) (output indicator) Instantaneous 1 and 4 output relay (NC) Instantaneous 1 and 3 output relay (NO) Power indicator Basic operation Power t Output Solid-state Timer H3BA-N 9 Dimensions Note: All units are in millimeters unless otherwise indicated. H3BA-N 15 78 63.7 6 48 0.7 13.6 PW UP 44.8 x 44.8 39 dia. 48 11 pins H3BA-N8H 15 78 6 63.7 48 0.7 13.6 PW UP 44.8 x 44.8 39 dia. 48 8 pins Dimensions with Set Ring 16.5 50 42 dia. 50 Time setting ring Panel cover Dimensions with Y92F-30 Flush Mounting Adapter Panel P3G Back Connecting Socket (sold separately) PW UP 58 52 42 48 Panel Cutout Note: The mounting panel thickness should be 1 to 5 mm. 0.5 R max. 45 +0.6 -0 10 Solid-state Timer H3BA-N 45+0.6 -0 (N) Dimensions with Y92F-70 Flush Mounting Adapter Panel Cutout Panel Adapter mounting hole Two, 4.5 dia. 52 to 53 R0.5 max. 45 88 0.15 PW UP 65 to 66 760.2 450.15 58 Dimensions with Y92F-71 Flush Mounting Adapter Panel 56 R0.5 max. 45 +0.5 -0 PW UP 58 55 +0.5 -0 68 450.2 430.2 50 +0.2 -0 Track Mounting Note: The mounting panel thickness should be 1 to 3.2 mm. Flush Mounting 15 H3BA-N 112.2* H3BA-N8H 109.9 101.3* 99 15 91.4 86.4 H3BA-N + Adapter Y92F-30 H3BA-N8H P3GA-11 Y92F-30 P3G-08 2.3* P2CF-08 2.3* P2CF-11 Note: These dimensions vary with the kind of DIN track (reference value). Solid-state Timer H3BA-N 11 Accessories (Order Separately) Track Mounting/Front Connecting Socket P2CF-08 Eight, M3.5 x 7.5 sems 3 7.8 Terminal Arrangement/ Internal Connections (Top View) 4.5 Surface Mounting Holes Two, 4.5 dia. or two, M4 70 max. 35.4 Two, 4.5 dia. holes 400.2 4 50 max. 20.3 max. P2CF-11 Eleven, M3.5 x 7.5 sems 3 4.5 Two, 4.5 dia. or two, M4 7.8 400.2 70 max. 35.4 Two, 4.5 dia. holes 4 50 max. 31.2 max. Back Connecting Socket Terminal Arrangement/ Internal Connections (Bottom View) P3G-08 27 dia. 45 45 P3GA-11 4.9 17 27 dia. 45 25.6 4.5 45 6.2 16.3 Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7.30.15 4.5 4.5 350.3 15 25 25 25 10 10 25 * L L: Length 1m 50 cm 1m 12 PFP-100N PFP-50N PFP-100N2 Solid-state Timer H3BA-N 350.3 27 270.15 1 15 25 25 10 25 L 25 10 15 24 29.2 1 1.5 End Plate Time Setting Ring/Panel Cover PFP-M 10 6.2 1 50 1.8 1.8 35.5 35.3 There are three types of Panel Covers (Y92P-48GL, Y92P-48GB, and Y92P-48GM), all of which are available in three colors. Use the most suitable type of Panel Cover with the design of the scaling plate according to the application. When setting a given time for the Timer, use of the Y92S-27 or Y92S-28 Time Setting Ring facilitates the time setting operation and minimizes possible setting errors by operators. The Time Setting Ring and Panel Cover should be used as a pair. 11.5 10 M4 x 8 pan head screw 1.3 4.8 Limiting the setting range Spacer PFP-S 16 12 5 Setting a specific time Time Setting Ring A (Y92S-27) and Panel Cover (Y92P-48GL, -48GB, or -48GM) Time Setting Ring B or C (Y92S-28), and Panel Cover (Y92P-48GL, -48GB, or 48GA) Y92S-27 Time Setting A Y92S-28 Time Setting B Y92S-28 Time Setting C Y92P-48GL Light Gray Y92P-48GB Black Y92P-48GM Medium Gray 34.8 44.3 16.5 Protective Cover Y92A-48B The protective cover protects the front panel, particularly the time setting section, against dust, dirt, and water. It also prevents the set value from being altered due to accidental contact with the time setting knob. Note: 1. The Y92A-48B Protective Cover is made of a hard plastic and therefore it must be removed to change the timer set value. Hold-down Clip Y92H-1 For PL08 Socket Y92H-2 For PF085A Socket 2. The Protective Cover cannot be mounted if the Panel Cover (sold separately) is used on the Timer. Y92A-48B PW UP Solid-state Timer H3BA-N 13 Installation Terminal Arrangement Gate input Start input Reset input H3BA-N (Contact Output) (-)(~) Power supply (+)(~) H3BA-N8H (Contact Output) Note: The delayed contacts of conventional timers are shown as follows: The contact symbol of the H3BA-N is expressed as follows because of its multiple operating modes: H A MODE (See note.) Note: 14 Power supply (+)(~) (-)(~) The output contact can be set to either instantaneous or time-limit contact using the output type selector located at the upper right corner of the front panel. Solid-state Timer H3BA-N The instantaneous contacts of conventional timers are shown as follows: Input Connections The inputs of the H3BA-N are no-voltage (short circuit or open) inputs. No-voltage Inputs No-contact Input (Connection to NPN open collector output sensor.) 12 to 24 VDC (sensor power supply) Sensor Contact Input No-contact Input (Connection to a voltage output sensor.) 12 to 24 VDC (sensor power supply) + DC power - supply + DC power - supply Timer Timer Timer Sensor Start/reset/ gate Start/reset/ gate Start/reset/ gate Input (0 V) (No. 2 pin) Input (0 V) (No. 2 pin) Input (0 V) (No. 2 pin) Operates with transistor ON Operates with relay ON Operates with transistor ON No-voltage Input Signal Levels No-contact input 1. Short-circuit level Transistor ON Residual voltage: 1 V max. Impedance when ON: 1 k max. 2. Open level Transistor OFF Impedance when OFF: 200 k min. Contact input Use contacts which can adequately switch 0.1 mA at 5 V Solid-state Timer H3BA-N 15 Safety Precautions CAUTION Minor electric shock may occasionally occur. Do not disassemble the product or touch the interior of the Timer. Minor burns may occasionally occur. Do not touch the product while power is being supplied or immediately after power is turned OFF. Minor fires may occasionally occur. Tighten terminal screws to a torque of 1.08 N*m so that they do not become loose. Minor electric shock may occasionally occur during operation. Install the terminal cover. Precautions for Correct Use Changing the Setting Do not change the time unit, time range, or operation mode while the Timer is in operation, otherwise the Timer may malfunction. Connecting the Operating Power Supply The H3BA-N@ contains a capacitor-drop power circuit. Use a sinusoidal power supply with a commercial frequency. Do not use power supplies with a high frequency component (such as inverter power supplies) for Timers with 110 or 220-VAC specifications. Using these power supplies can damage internal circuits. Minor electric shock, fire, or malfunction may occasionally occur. Do not allow metal fragments, lead wire scraps, or chips from processing during installation to fall inside the Timer. If voltages other than the rated voltage is applied, the internal components may be damaged. The internal element (varistor) will be damaged if a voltage of higher than 100 VAC is applied to the 24VDC line. Precautions for Safe Use Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately or the Timer may not be reset or a timer error could result. Please observe the following precautions for safe use of this product. A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. Environmental Precautions Store the Timer within specified ratings. If the Timer has been stored at -10C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. If the wiring to the terminal 2 (common terminal for both the power supply and input signals) is broken, the internal circuit will be destroyed. Use the Timer within the specified ratings for operating temperature and humidity. 5, 6, 7 G, S, R Do not operate the Timer in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. Input terminal H3BA-N Do not use the Timer in locations subject to excessive dust, corrosive gas, or direct sunlight. Closed 2 Do not use the Timer in locations subject to vibration or shock. Extended use in such locations may result in damage due to stress. Install the Timer well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. Usage Precautions Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. Pay careful attention to polarity to prevent wrong connections when wiring terminals. Input/Output An appropriate input will be applied to the input signal terminals of the Timer when one of the input terminals (terminals 5, 6, and 7) and the common terminal (terminal 2) for the input signals are shortcircuited. Do not attempt to connect any input terminal to any terminal other than the common terminal or to apply voltage across other than the specified input and common terminals or the internal circuits of the Timer may be damaged. Internal elements may be destroyed if a voltage outside the rated voltage is applied. Maintain voltage fluctuations in the power supply within the specified range. The Timer uses a transformerless power supply. Do not touch the input terminals while the supply voltage is being applied, otherwise an electric shock may occur. 10 10 Power supply AC or DC (See note 2) H3BA-N 5, 6, 7 G, S, R Input contact Input terminal 2 (see note 1) Note: 1. Power supply terminal 2 is a common terminal for the input signals (G, S, R) to the Timer. Never use terminal 10 as the common terminal for this purpose, otherwise the internal circuit of the Timer may be damaged. 2. Do not connect a relay or any other load between these two points, otherwise the internal circuit of the Timer may be damaged due to the high-tension voltage applied to the input terminals. 16 Solid-state Timer H3BA-N Operating Time Setting Mounting When setting the operating time, do not turn the setting knob beyond its scale range. For precise time setting, conduct operation tests by adjusting the setting knob. Surface Mounting The accuracy of the operating time of the Analog Timer is indicated by the percentage value on the basis of the full-scale time. The absolute fluctuation value will not be improved by changing the time setting. Therefore, when selecting the model, be sure that the application will be able to use a time setting as close as the full-scale time setting of the Timer. Others When conducting a dielectric test, impulse voltage test, or insulation resistance test between the electric circuit and non-current-carrying metal parts of the Timer mounted to a control panel, be sure to take the following steps. These steps will prevent the internal circuitry of the Timer from damage that may be caused if a machine on the control panel has an improper dielectric strength or insulation resistance. 1. Separate the Timer from the circuitry of the control panel by disconnecting the socket from the Timer or wires. 2. Short-circuit all terminals of the Timer. If any device with no-contact output, such as a proximity sensor, photoelectric sensor, or SSR, is directly connected to the Timer, current leakage from the device may cause Timer malfunction. Be sure to test the device with the Timer before using the device for actual applications. There is no particular restriction on surface mounting directions, but be sure that the Timer is securely mounted horizontally. P2CF Socket When mounting the Timer vertically with the P2CF Socket, consider the movable hooks and be sure that there is a 20-mm space on each of the upper and lower parts of the Socket. Duct Hook P2CF-08 Panel Before using the Timer to switch inductive loads, be sure to connect a surge absorbing element to the Timer in order to prevent the Timer from malfunction and damage. A diode is an example of a surge absorbing element for DC circuits and a surge absorber is an example of a surge absorbing element for AC circuits. Do not leave the Timer in time-up condition for a month or longer in places with high temperatures, otherwise the internal parts, such as an electrolytic capacitor, of the Timer may be damaged. Use the Timer with an appropriate relay so that the Timer will not be left in time-up condition for a long time. If the Timer is mounted in contact with a mounting surface, the service life of internal parts may be shortened. Provide at least 10 mm between the Timer and the mounting surface to prolong the service life of the Timer. When the Timer is reset right after the Timer goes into time-up condition, be sure to provide the Timer with an appropriate circuit configuration considering the resetting time of the Timer so that a sequential error will not result. The Timer uses the constant value read method. Be careful when changing the set value because the output of the Timer will be ON when the set value coincides with the count value. Be sure that the casing of the Timer is free from organic solvents, such as paint thinner and benzene, strong acid, and alkali solvents, which will damage the casing. Note: It is impossible to connect more than two Timers in parallel. Solid-state Timer H3BA-N 17 Dismounting PL Socket 1. Secure the Socket to the panel surface with screws and insert the F-shaped hook into the sockets. Surface Mounting with P2CF 2. Connect the Timer to the Socket and press the tip of each hook by hand. Panel Mounting Loosen the screws of the Flush Mounting Adapter, spread open the hooks, and remove the Mounting Adapter. Panel Mounting When the Y92F-30 Flush Mounting Adapter is used, insert the Timer into the square hole from the front side of the panel and put on the Flush Mounting Adapter from the rear side of the Timer. Press the Flush Mounting Adapter so that the space between the Flush Mounting Adapter and the panel is reduced as much as possible, and secure the Flush Mounting Adapter with screws. Panel Screw Y92F-30 When using the US08, be sure to use 10.5-dia. max. multi-conductor cable or 3-dia. max. insulated stranded wire for wiring. When the Y92F-40, Y92F-70 or Y92F-71 Flush Mounting Adapter is used, just insert the Timer into the square panel hole. If the panel coating is too thick and the hooks do not click, spread open the hooks appropriately to the left and right after inserting the Timer to the hole. Spread open the hooks to the left and right. Panel The illustration is an ex ample with the Y92F-70. Spread open the hooks to the left and right. 18 Solid-state Timer H3BA-N When the Y92F-40, Y92F-70, Y92F-71 Mounting Adapter is used, press the hook inwards with the thumb and index finger of both hands, and press the Timer towards the front side. Solid-state Timer H3BA-N 19 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron's payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in "break down" situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, "including" means "including without limitation"; and "Omron Companies" (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. Note: This datasheet is provided as a guideline for selecting products. Do not use this document to operate the Unit. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE OMRON ARGENTINA * SALES OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 * www.omron247.com Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE OMRON CHILE * SALES OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE OTHER OMRON LATIN AMERICA SALES Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com 54.11.4783.5300 Cat. No. L093-E1-02A (c) 2009 Omron Electronics LLC Specifications are subject to change without notice. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: H3BA-N8H-110VAC H3BA-N8H-220-VAC H3BA-N 110 VAC H3BA-N AC220V H3BA-N 24 VDC